DocumentCode :
2457077
Title :
Sliding mode observer design for universal flexible power management (Uniflex-PM) structure
Author :
Almaleki, Masoud ; Wheeler, Pat ; Clare, Jon
Author_Institution :
PEMC Group, Univ. of Nottingham, Nottingham
fYear :
2008
fDate :
10-13 Nov. 2008
Firstpage :
3321
Lastpage :
3326
Abstract :
In this paper a sliding mode observer is designed and applied to the Uniflex-PM structure in order to observe the capacitor voltages. The objective of the Uniflex-PM project is to develop advanced power conversion technique to meet future needs of electricity networks. Uniflex-PM can provide optimized connection of distributed energy resources, integration and management of energy storage, optimized utilization of the transmission/distribution infrastructure, a high quality of supply and coordinated control across the network. The strategic objectives are to secure a clean, sustainable & economic energy supply for the EU and a new modular power conversion architecture for universal applications. The main characteristics that make Uniflex-PM a unique choice for power system applications is the modular structure and the interleaved connection between phases at different ports. Each module comprises two H-bridges connected as an AC/DC converter and a DC/DC converter with a medium frequency transformer isolation. By having interleaved connection between phases, Uniflex-PM is able to operate under unbalanced conditions. In a two-port Uniflex-PM there are nine capacitors whose voltages, are needed in feedback loops of the system controller, which includes the voltage control loop and balancer. This means that nine voltage transducers are required. The use of so many transducers can make the system unreliable, thus it is desirable to observe the capacitor voltages instead of measuring them. The sliding mode observer (SMO) via equivalent control approach has been selected to be applied to the Uniflex-PM because of its robustness against a class of uncertainties in system equations. Simulation results from SABER are used to demonstrate the use of this observer technique.
Keywords :
AC-AC power convertors; DC-DC power convertors; feedback; observers; power system control; variable structure systems; voltage control; AC-DC converter; DC-DC converter; EU; SABER; Uniflex-PM; balancer; capacitor voltages; electricity networks; feedback loops; medium frequency transformer isolation; modular power conversion architecture; sliding mode observer design; universal flexible power management structure; voltage control loop; voltage transducers; Capacitors; Control systems; DC-DC power converters; Energy conversion; Energy management; Energy resources; Power conversion; Sliding mode control; Transducers; Voltage control;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Industrial Electronics, 2008. IECON 2008. 34th Annual Conference of IEEE
Conference_Location :
Orlando, FL
ISSN :
1553-572X
Print_ISBN :
978-1-4244-1767-4
Electronic_ISBN :
1553-572X
Type :
conf
DOI :
10.1109/IECON.2008.4758492
Filename :
4758492
Link To Document :
بازگشت