• DocumentCode
    2460948
  • Title

    Unbalanced three-phase control using offset-voltage for H-bridge multilevel inverter with faulty power cells

  • Author

    Park, Young-Min ; Lyoo, Han-Seoung ; Lee, Hyun-Won ; Jung, Myung-Gil ; Lee, Se-Hyun ; Yoo, Ji-Yoon

  • Author_Institution
    Hyundai Heavy Ind. Co. Ltd., Seoul
  • fYear
    2008
  • fDate
    15-19 June 2008
  • Firstpage
    1790
  • Lastpage
    1795
  • Abstract
    In this paper, unbalanced three-phase control method is proposed to increase the fault tolerance for H-bridge multilevel inverter under the conditions of faulty power cells. It is possible to generate a balanced three-phase line-to-line voltage by phase-shifting and bypassing faulty power cells with a minimum voltage drop. In this method, the concept of voltage modulation by using offset voltage is applied to an unbalanced three-phase control method. Especially, it is possible to use the maximum output voltage of inverter by adopting the real time unbalanced control method of phase voltage irrespective of the fault location and the number of disabled power cells. Also, the feasibility of the proposed method is proved by the H-bridge multilevel inverter test composed of 7-level.
  • Keywords
    bridge circuits; invertors; voltage control; H-bridge multilevel inverter; fault tolerance; faulty power cells; inverter output voltage; offset-voltage; three-phase line-to-line voltage; unbalanced three-phase control; voltage drop; voltage modulation; Fault location; Fault tolerance; Industrial control; Power generation; Power system reliability; Power transformers; Pulse width modulation inverters; Switches; Testing; Voltage control;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 2008. PESC 2008. IEEE
  • Conference_Location
    Rhodes
  • ISSN
    0275-9306
  • Print_ISBN
    978-1-4244-1667-7
  • Electronic_ISBN
    0275-9306
  • Type

    conf

  • DOI
    10.1109/PESC.2008.4592203
  • Filename
    4592203