Abstract :
In May 1996 the international comparison of ac-dc voltage transfer standards at lowest level of uncertainty, using a multijunction thermal converter as the travelling standard, will be completed. Intermediate results show an agreement of the majority of the participating laboratories of better than 0, 4 ppm at the frequency of 1 kHz, 1 ppm at 20 kHz, 1, 8 ppm at 100 kHz and 16 ppm at 1 MHz.
Keywords :
measurement errors; measurement standards; voltage measurement; voltage-frequency convertors; 1 MHz; 1 kHz; 100 kHz; 20 kHz; CCE comparison; May 1996; ac-dc voltage transfer standards; participating laboratories; travelling standard; uncertainty; Analog-digital conversion; Frequency; Laboratories; Large-scale systems; Manufacturing; Particle measurements; Testing; Thermal resistance; Uncertainty; Voltage measurement;