• DocumentCode
    2461844
  • Title

    A non-invasive technique for fault diagnosis of SMPS

  • Author

    Amaral, Acácio M R ; Cardoso, A. J Marques

  • Author_Institution
    Polytech. Inst. of Coimbra/ISEC-DEIS, Coimbra
  • fYear
    2008
  • fDate
    15-19 June 2008
  • Firstpage
    2097
  • Lastpage
    2102
  • Abstract
    This paper presents an on-line non-invasive fault diagnostic technique that can predict the condition of aluminum electrolytic capacitors used in the output filter of switch mode power supplies (SMPS). The aluminum electrolytic capacitors aging process manifest itself by the increase of their equivalent series resistance (ESS). The proposed method uses the input current, the output voltage ripple, the discrete Fourier transform (DFT) and the least mean squares (LMS) algorithm to predict the ESR value.
  • Keywords
    ageing; aluminium; discrete Fourier transforms; electrolytic capacitors; fault diagnosis; least mean squares methods; power supply circuits; Al; aging process; aluminum electrolytic capacitors; discrete Fourier transform; equivalent series resistance; input current; least mean squares algorithm; on-line noninvasive fault diagnostic technique; output filter; output voltage ripple; switch mode power supplies; Aging; Aluminum; Capacitors; Discrete Fourier transforms; Electronic switching systems; Fault diagnosis; Filters; Switched-mode power supply; Switches; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Power Electronics Specialists Conference, 2008. PESC 2008. IEEE
  • Conference_Location
    Rhodes
  • ISSN
    0275-9306
  • Print_ISBN
    978-1-4244-1667-7
  • Electronic_ISBN
    0275-9306
  • Type

    conf

  • DOI
    10.1109/PESC.2008.4592252
  • Filename
    4592252