• DocumentCode
    2462163
  • Title

    A micropotentiometer-based system for low-voltage calibration of alternating voltage measurement standards

  • Author

    Budovsky, I.

  • Author_Institution
    Nat. Meas. Lab., CSIRO, Lindfield, NSW, Australia
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    497
  • Lastpage
    498
  • Abstract
    The paper describes a new ac-dc transfer standard developed at the National Measurement Laboratory. It enables calibration of ac-dc transfer and absolute ac voltage standards to be made in the range of voltages from 2 mV to 500 mV, with an uncertainty of 10 to 1000 ppm in the frequency range 10 Hz to 1 MHz.
  • Keywords
    calibration; measurement standards; potentiometers; voltage measurement; 10 Hz to 1 MHz; 2 to 500 mV; National Measurement Laboratory; absolute ac voltage standards; ac-dc transfer; alternating voltage measurement standards; low-voltage calibration; measurement uncertainty; micropotentiometer; Australia; Calibration; Frequency; Laboratories; Measurement standards; Physics; Resistors; Standards development; Thermal resistance; Voltage measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547184
  • Filename
    547184