• DocumentCode
    2462392
  • Title

    Evaluation of the calculable high frequency ac/dc standard

  • Author

    vanMullem, C.J. ; Janssen, W.J.G.D. ; deVreede, J.P.M.

  • Author_Institution
    NMi van Swinden Lab., Delft, Netherlands
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    499
  • Lastpage
    500
  • Abstract
    The calculable HF ac/dc transfer standard has been developed at VSL. An improved model which contains a more detailed description of the thermal element with the end disc and the housing, is presented together with measurements. The major result is a calculated shift of about 4000 ppm in the ac/dc difference at 100 MHz. Based on this model, a 2 V standard is under development.
  • Keywords
    measurement standards; voltage measurement; 100 MHz; 2 V; HF; VSL; ac/dc standard; end disc; housing; modelling; thermal element; transfer standard; Capacitance; Conducting materials; Conductivity; Frequency measurement; Measurement standards; Parameter estimation; Predictive models; Tellurium; Uncertainty; Wire;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547185
  • Filename
    547185