Title :
Observability preservation under sensor failure
Author :
Commault, Christian ; Dion, Jean-Michel ; Trinh, Do Hieu
Author_Institution :
Lab. d´´Automatique de Grenoble, CNRS, Saint Martin d´´Heres
Abstract :
This paper is concerned with the study of observability in a structured framework. It turns out that the system is structurally observable if and only if the system is output connected and contains no contraction. We focus our attention on the observability preservation under sensor failure. We consider linear observable systems and we wonder if a given system remains observable in case of sensor failure. More precisely we will characterize among the sensors those which are critical i.e. which failure leads to observability loss, those which are useless for observability purpose and the set of those which are useful without being critical. Using a graph approach we classify the sensors with respect to their importance for output connection preservation, contraction avoidance and then observability preservation under sensor failure
Keywords :
linear systems; observability; sensors; linear observable systems; observability preservation; sensor failure; Chemical engineering; Chemical sensors; Controllability; Failure analysis; Linear systems; Observability; Sensor phenomena and characterization; Sensor systems; USA Councils; Vectors;
Conference_Titel :
Decision and Control, 2006 45th IEEE Conference on
Conference_Location :
San Diego, CA
Print_ISBN :
1-4244-0171-2
DOI :
10.1109/CDC.2006.377111