Abstract :
To evaluate the functional effect of a coronary artery stenosis on the dependent myocardium, digitized coronary angiograms (DCAs) were recorded. The DCAs, acquired during heart catheterization, provide information about myocardial perfusion and coronary flow reserve of areas supplied by this coronary artery. For each analysis the myocardium is separated into different regions of interest (ROIs); 16 ROIs in the distribution of the LCA and 8 ROIs for the RCA. In addition to that, the ROIs of the diseased vessels are divided into ROIs which are proximal, within and distal to the stenosis. Using a semiautomatic procedure, densograms are constructed from which the parameter rise time is calculated
Keywords :
angiocardiography; blood flow measurement; densitometry; haemorheology; image segmentation; medical image processing; muscle; coronary flow reserve determination; densitometric measurements; densograms; digitized coronary angiograms; diseased vessels; heart catheterization; medical diagnostic imaging; myocardial perfusion determination; parameter rise time; regions of interest; selective classification; semiautomatic procedure; stenosis; Angiography; Arteries; Biomedical imaging; Blood flow; Cardiology; Density measurement; Fluid flow measurement; Heart; Image processing; Myocardium;
fLanguage :
English