• DocumentCode
    2468657
  • Title

    Field measurement of winter air quality of the typical rural building in southwest of Shandong Province

  • Author

    Youjun Wang ; Yanming Kang ; Ke Zhong ; Yuankai Li ; Youjun Wang

  • fYear
    2011
  • fDate
    24-26 June 2011
  • Firstpage
    5979
  • Lastpage
    5982
  • Abstract
    For investigating the winter air quality of the typical rural building in southwest of Shandong province, concentrations of particles (PM1.0), gaseous pollutants (CO and CO2) in the main room and courtyard were measured. Concentrations of contaminants in both rooms appeared consistent trend, with peak values in the three periods of mealtimes. Contaminants in the main rooms mainly derived from the courtyard, as well as contribution of occupants´ activity. Using stove to warm the main room produced substantive gaseous contaminants, especially higher concentration of CO when stove was quenching. Comparing biomass and fossil fuel, the former produced more particles, while the latter made more gaseous pollutants. In addition, setting off fireworks seriously contaminated air quality of rural buildings, and concentrations of contaminants depended on the patterns of fireworks.
  • Keywords
    Air pollution; Biomass; Buildings; Coal; Fires; Heating; carbon dioxide; carbon monoxide; particles; rural building;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Remote Sensing, Environment and Transportation Engineering (RSETE), 2011 International Conference on
  • Conference_Location
    Nanjing, China
  • Print_ISBN
    978-1-4244-9172-8
  • Type

    conf

  • DOI
    10.1109/RSETE.2011.5965717
  • Filename
    5965717