DocumentCode :
2469561
Title :
2C-1 A Post-Beamforming 2D Pseudoinverse Filter for Coarsely Sampled Ultrasound Arrays
Author :
Wan, Yayun ; Ebbini, Emad S.
Author_Institution :
Univ. of Minnesota, Minneapolis
fYear :
2007
fDate :
28-31 Oct. 2007
Firstpage :
21
Lastpage :
24
Abstract :
Beamforming artifacts due to coarse discretization of imaging apertures represent a significant barrier toward the use of array probes in high frequency ultrasound (HFUS) applications. In this paper, we present a new design approach for two-dimensional (2D) regularized Pseudoinverse filters suitable for restoring imaging contrast in systems employing coarsely sampled arrays. The approach is based on a discretized 2D imaging model for linear arrays, and the imaging operator can be represented with a block Toeplitz matrix with the blocks themselves being Toeplitz. With sufficiently large grid size in the axial and lateral directions, it is possible to replace this Toeplitz-block block Toeplitz (TBBT) operator with its circulant-block block circulant (CBBC) equivalent. This leads to a computationally- efficient implementation of the regularized Pseudoinverse filtering approach using the 2D fast Fourier transform (FFT). Using FIELD II, we present simulation data of the 2D point spread functions (PSFs) and a cyst phantom for imaging systems employing linear arrays with fine and coarse sampling of the imaging aperture. The 6-dB axial and lateral dimensions of the PSF, the main-lobe grating-lobe ratio (MGR) and contrast ratio (CR) are computed for the coarsely-sampled array with different levels of regularization to demonstrate the trade off between contrast and spatial resolutions. These results demonstrate approximate sigmoid functions with respect to log10beta which reveals a smooth, well-behaved regularization process of this algorithm.
Keywords :
biomedical ultrasonics; fast Fourier transforms; image restoration; medical image processing; ultrasonic arrays; ultrasonic imaging; 2D fast Fourier transform; 2D point spread functions; FIELD II; HFUS applications; array probes; beamforming artifacts; block Toeplitz matrix; circulant-block block circulant operator; coarse discretization; coarsely sampled ultrasound arrays; cyst phantom; discretized 2D imaging model; filter design; high frequency ultrasound; imaging apertures; imaging contrast restoration; post-beamforming 2D pseudoinverse filter; sigmoid functions; Apertures; Array signal processing; Computational modeling; Fast Fourier transforms; Filtering; Filters; Frequency; Imaging phantoms; Probes; Ultrasonic imaging;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Ultrasonics Symposium, 2007. IEEE
Conference_Location :
New York, NY
ISSN :
1051-0117
Print_ISBN :
978-1-4244-1384-3
Electronic_ISBN :
1051-0117
Type :
conf
DOI :
10.1109/ULTSYM.2007.19
Filename :
4409592
Link To Document :
بازگشت