DocumentCode :
2470538
Title :
Experimental evaluation of space vector oriented active DC-side current balancing of two parallel connected three-phase three-switch buck-type unity power factor rectifier systems
Author :
Baumann, Martha ; Kolar, Joham W.
Author_Institution :
Inst. of Electr. Drives & Machines, Vienna Univ. of Technol., Austria
fYear :
2002
fDate :
2002
Firstpage :
317
Lastpage :
324
Abstract :
In this paper the parallel connection of two three phase buck-type unity power factor rectifier systems is investigated experimentally for a 10 kW DSP-controlled prototype. There, a space vector modulation scheme is employed which shows all advantages of interleaved operation of the two systems. Three control schemes for active DC-side current balancing are described. The control schemes do differ concerning their control action and concerning additional switching losses. All control structures discussed in this paper are based on employing an additional free-wheeling states which do allow influence of the rate of change of the DC-side currents and can therefore be used for DC-side current balancing.
Keywords :
digital control; digital signal processing chips; electric current control; losses; power factor; rectifying circuits; switching convertors; 10 kW; DSP-controlled prototype; control action; control structures; free-wheeling states; interleaved operation; parallel connected rectifier systems; space vector modulation scheme; space vector oriented active DC-side current balancing; switching losses; three-phase three-switch buck-type rectifier systems; unity power factor rectifier systems; Frequency; Laboratories; Power electronics; Power harmonic filters; Prototypes; Pulse width modulation; Reactive power; Rectifiers; Switches; Voltage;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Telecommunications Energy Conference, 2002. INTELEC. 24th Annual International
Print_ISBN :
0-7803-7512-2
Type :
conf
DOI :
10.1109/INTLEC.2002.1048674
Filename :
1048674
Link To Document :
بازگشت