Abstract :
We have recently proposed a novel CO index, namely pulse time reflection ratio (PTRR), which is extracted from photoplethysmogram and electrocardiogram and measurable from wearable devices, and proved that this index is potentially useful for dynamic CO monitoring in a preliminary study carried out on young, healthy subjects. In this study, we presented an evaluation of this technique against impedance cardiography on 64 subjects undergoing incremental maximal exercise testing, including 15 healthy elderly, 19 cardiovascular patients and 30 heart failure patients. Results showed significant intra-subject correlations (r) between PTRR and reference CO in all subjects (mean r: 0.93, p<;0.05) and no significant differences on mean r among subject populations (one-way ANOVA, p=0.48). With further development and testing on mobile subjects, this technique can be applied for long-term CO monitoring at home or in other dynamic situations.
Keywords :
biomechanics; biomedical measurement; cardiovascular system; electrocardiography; geriatrics; medical disorders; patient monitoring; photoplethysmography; cardiac output index; cardiovascular failure patients; dynamic exercise; dynamic monitoring; electrocardiogram; healthy elderly; heart failure patients; impedance cardiography; incremental maximal exercise testing; photoplethysmogram; pulse time reflection ratio; wearable device; Correlation; Diseases; Electrocardiography; Heart; Impedance; Indexes; Cardiac Output; Cardiovascular Diseases; Diagnosis, Computer-Assisted; Electroencephalography; Exercise Test; Female; Health Status Indicators; Heart Failure; Humans; Male; Photoplethysmography; Reference Values; Reproducibility of Results; Sensitivity and Specificity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE
Conference_Location :
Boston, MA
ISSN :
1557-170X
Print_ISBN :
978-1-4244-4121-1
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2011.6090365
Filename :
6090365
Link To Document :
بازگشت