    Evaluation of a novel cardiac output index on healthy elderly, cardiovascular and heart failure patients during dynamic exercise

  • Author

    Wang, L. ; Poon, C.C.Y. ; Yip, Gabriel ; Yu, Cheuk Man ; Zhang, Y.T.

  • Author_Institution
    Dept. of Electron. Eng., Chinese Univ. of Hong Kong, Hong Kong, China
  • fYear
    2011
  • fDate
    Aug. 30 2011-Sept. 3 2011
  • Firstpage
    1515
  • Lastpage
    1518
  • Abstract
    We have recently proposed a novel CO index, namely pulse time reflection ratio (PTRR), which is extracted from photoplethysmogram and electrocardiogram and measurable from wearable devices, and proved that this index is potentially useful for dynamic CO monitoring in a preliminary study carried out on young, healthy subjects. In this study, we presented an evaluation of this technique against impedance cardiography on 64 subjects undergoing incremental maximal exercise testing, including 15 healthy elderly, 19 cardiovascular patients and 30 heart failure patients. Results showed significant intra-subject correlations (r) between PTRR and reference CO in all subjects (mean r: 0.93, p<;0.05) and no significant differences on mean r among subject populations (one-way ANOVA, p=0.48). With further development and testing on mobile subjects, this technique can be applied for long-term CO monitoring at home or in other dynamic situations.
  • Keywords
    biomechanics; biomedical measurement; cardiovascular system; electrocardiography; geriatrics; medical disorders; patient monitoring; photoplethysmography; cardiac output index; cardiovascular failure patients; dynamic exercise; dynamic monitoring; electrocardiogram; healthy elderly; heart failure patients; impedance cardiography; incremental maximal exercise testing; photoplethysmogram; pulse time reflection ratio; wearable device; Correlation; Diseases; Electrocardiography; Heart; Impedance; Indexes; Cardiac Output; Cardiovascular Diseases; Diagnosis, Computer-Assisted; Electroencephalography; Exercise Test; Female; Health Status Indicators; Heart Failure; Humans; Male; Photoplethysmography; Reference Values; Reproducibility of Results; Sensitivity and Specificity;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE
  • Conference_Location
    Boston, MA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4121-1
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2011.6090365
  • Filename
    6090365