DocumentCode
2472236
Title
Onset voltage of negative corona in point-cup gaps
Author
El-Bahy, M.M.
Author_Institution
Fac. of Eng. at Shubra, Zagazig Univ., Cairo, Egypt
fYear
2002
fDate
2002
Firstpage
159
Lastpage
163
Abstract
In this paper, the onset voltage of negative corona is theoretically predicted for point-cup gaps positioned in air. The method of calculation is based on the criterion developed for the formation of repetitive negative corona Trichel pulses. Field distributions are determined through charge simulation method coupled with least-square error method for optimal charge distribution and accurate field computation. Different gap dimensions are studied. Accurate distributions, not only for the potential but also for the electric field have been obtained throughout the entire interelectrode space. Negative onset voltage of corona is calculated at different gap dimensions and different air pressures.. The values of calculated onset voltages agreed well with those measured experimentally within 5%.
Keywords
air; corona; least squares approximations; air pressure; charge distribution; charge simulation method; electric field distribution; electric potential distribution; least square error method; negative corona; onset voltage; point-cup gap; Computational modeling; Corona; Distributed computing; Electrodes; Electron emission; Ionization; Power transmission lines; Space technology; Transmission line measurements; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
Print_ISBN
0-7803-7502-5
Type
conf
DOI
10.1109/CEIDP.2002.1048760
Filename
1048760
Link To Document