• DocumentCode
    2472324
  • Title

    7D-5 Detection and Sizing of Delaminations in Composites Using Modally-Selective Lamb-Wave Transducers

  • Author

    Petculescu, Gabriela ; Krishnaswamy, Sridhar ; Achenbach, Jan D.

  • Author_Institution
    Univ. of Louisiana at Lafayette, Lafayette
  • fYear
    2007
  • fDate
    28-31 Oct. 2007
  • Firstpage
    597
  • Lastpage
    599
  • Abstract
    This work addresses several aspects of damage detection and evaluation in composite laminates, in the general context of structural health monitoring. A group delay measurement technique is proposed using modally-selective Lamb-wave transducers for the detection and sizing of delaminations in woven quasi-isotropic and carbon-epoxy cross- ply composites. Unlike amplitude or energy based Lamb-wave methods, this method is insensitive to transducer coupling. The first asymmetric Lamb mode was used in the investigation because of its extended low-dispersion zone and its relatively short wavelength, at any given frequency. The transducers used to excite and detect the Lamb waves are array-type transducers able to select a specific mode. First, inserts of different sizes and different types introduced in the mid-plane during fabrication in a carbon-epoxy plain-weave quasi-isotropic composite panel were investigated. A simple "ray" analysis taking into account the observed change in group velocity and the measured time delay induced geometrically by the defect accounts accurately for the size of the defects. The same technique was applied to the detection of impact damage in cross-ply carbon-epoxy laminates. The naturally produced defects are more complex as an impact produces delaminations distributed at multiple lamina interfaces throughout the thickness of the panel, as well as matrix damage and fiber cracking. The cumulative effect of the complex damage upon the propagating wave is, again, to lower its group velocity. The time-delay measured vs. the accumulation of impact damage is significant and it correlates with the damage extent. The results are repeatable and consistent, suggesting time-delay as a reliable damage parameter for quantitative monitoring of delaminations and impact damage in composites.
  • Keywords
    condition monitoring; delamination; laminates; surface acoustic wave transducers; surface acoustic waves; ultrasonic materials testing; Lamb wave transducers; composites; damage detection; delamination detection; delamination sizing; group velocity; laminates; structural health monitoring; time delay; transducer coupling; Delamination; Delay; Fabrication; Frequency; Laminates; Measurement techniques; Monitoring; Size measurement; Transducers; Velocity measurement;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2007. IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1051-0117
  • Print_ISBN
    978-1-4244-1384-3
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2007.155
  • Filename
    4409728