Title :
Voltage-current phase angle measurements during aging tests of polymer insulators
Author :
Que, Weiguo ; Casale, Edgar P. ; Sebo, Stephen A.
Author_Institution :
Dept. of Electr. Eng., Ohio State Univ., Columbus, OH, USA
Abstract :
An accurate method for the measurement of the voltage-current phase angle is implemented in a data acquisition system during aging tests of polymer insulators. The voltage-current phase angle and surface resistance measurement results in the course of aging tests are presented and analyzed. The test results show the trends of the phase angle and surface resistance changes during "fog off\´ and "fog on" periods of fog chamber tests.
Keywords :
ageing; insulator testing; polymer insulators; surface resistance; aging test; data acquisition system; fog chamber test; outdoor insulation; polymer insulator; surface resistance measurement; voltage-current phase angle measurement; Aging; Data acquisition; Electrical resistance measurement; Goniometers; Insulator testing; Phase measurement; Plastic insulation; Polymers; Surface resistance; Voltage;
Conference_Titel :
Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
Print_ISBN :
0-7803-7502-5
DOI :
10.1109/CEIDP.2002.1048811