DocumentCode :
2473666
Title :
Estimation of patient compliance in application of adherent mobile cardiac telemetry device
Author :
Engel, Jonathan M. ; Chakravarthy, Niranjan ; Katra, Rodolphe P. ; Mazar, Scott ; Libbus, Imad ; Chavan, Abhi
Author_Institution :
Corventis, Inc., St. Paul, MN, USA
fYear :
2011
fDate :
Aug. 30 2011-Sept. 3 2011
Firstpage :
1536
Lastpage :
1539
Abstract :
In an in home usage outpatient setting, patient compliance is a key factor in determining the adoption and efficacy of treatment for any illness and is paramount for patient dependent medical technologies such as mobile patient monitoring systems. As a leader in the development of these technologies, Corventis has deployed its NUVANT™ Mobile Cardiac Telemetry System to thousands of patients around the world. The NUVANT system includes an externally worn adherent sensing device, the PiiX, whose proper application is critical to the on-patient longevity and thus performance of the NUVANT system. Patient compliance in this context is a universal challenge for such patient-applied adherent devices. Understanding and tracking a problem is key to solving it and the integrated suite of vital sign sensors in the Corventis PiiX offers a unique opportunity for extracting patient application compliance information from the incoming health data. Analysis of data from 5000 randomly selected patients has shown that improper application of the PiiX is a factor in 2.3% of patients. However, no reduction in adherent device longevity or performance was observed. Such information is a valuable feedback metric for product design, instructions for use, packaging of medical technologies, level of customer support and replacement costs.
Keywords :
biomedical electronics; biomedical telemetry; cardiology; patient monitoring; patient treatment; sensors; NUVANT Mobile Cardiac Telemetry System; PiiX; adherent mobile cardiac telemetry device; externally worn adherent sensing device; home usage outpatient setting; mobile patient monitoring systems; patient application compliance information; patient applied adherent devices; patient compliance estimation; patient dependent medical technologies; patient treatment; vital sign sensors; Accelerometers; Gravity; Medical services; Monitoring; Performance evaluation; Sensors; Skin; Acceleration; Actigraphy; Electrocardiography; Humans; Monitoring, Ambulatory; Patient Compliance; Plethysmography, Impedance; Telemetry;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE
Conference_Location :
Boston, MA
ISSN :
1557-170X
Print_ISBN :
978-1-4244-4121-1
Electronic_ISBN :
1557-170X
Type :
conf
DOI :
10.1109/IEMBS.2011.6090448
Filename :
6090448
Link To Document :
بازگشت