• DocumentCode
    2473689
  • Title

    9F-2 Heat Conductive Array Transducer for Phase-Conversion Molecular Imaging

  • Author

    Azuma, Takashi ; Sonoda, Shiho ; Kawabata, Ken-ichi ; Umemura, Shin-ichiro

  • Author_Institution
    Hitachi Central Res. Lab., Tokyo
  • fYear
    2007
  • fDate
    28-31 Oct. 2007
  • Firstpage
    836
  • Lastpage
    839
  • Abstract
    A heat conductive array transducer was designed for transmitting high power ultrasound as well as transmitting and receiving wideband pulse waves. In phase-conversion ultrasonic molecular imaging, tissue-selective nano-droplets are converted to contrast microbubbles by a long duration ultrasonic pulse with a relatively high amplitude. When a conventional imaging array transducer was used, sensitivity of transducer decreased caused by some breakdown processes. In this study, we firstly examined the breakdown process based on experiments and numerical simulations. The experimental result was consistent with the simulation result assuming peeling of the adhesive between two PZT layers. A new transducer structure using a heat conducting acoustic isolation layer (AIL) on a metal heat sink block was conceived to inhibit this type of breakdown while maintaining the wide bandwidth for imaging with a high resolution. Heat generated in the PZT and adjacent layers can diffuse into a metal heat conductor through the AIL. Since the AIL reflects pulses, a possible unwanted response due to reflection at the opposite side of the metal block will be suppressed. The temperature rise and the ultrasonic pulse response of the transducer were calculated using PZFlex. The temperature rise in the transducer immediately after driving at 40 V for 25 s with 1% duty ratio was 37 degrees for the proposed structure, much lower than that for the conventional structure of 56 degrees. No serious unwanted response was observed for the proposed structure. These results show that the proposed structure will be useful for a high-power wideband phased array transducer.
  • Keywords
    biomedical ultrasonics; heat conduction; piezoelectric transducers; ultrasonic imaging; ultrasonic transducer arrays; PZFlex; PZT; PZT layers; contrast microbubbles; heat conducting acoustic isolation layer; heat conductive array transducer; heat sink block; high-power wideband phased array transducer; long duration ultrasonic pulse; phase-conversion molecular imaging; tissue-selective nanodroplets; Acoustic transducers; Electric breakdown; Heat sinks; Molecular imaging; Phased arrays; Temperature; Ultra wideband technology; Ultrasonic imaging; Ultrasonic transducer arrays; Ultrasonic transducers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2007. IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1051-0117
  • Print_ISBN
    978-1-4244-1384-3
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2007.214
  • Filename
    4409787