Abstract
Large generators for use with steam and gas turbines are subject to high mechanical and electrical stress which may lead to deterioration of the insulation. The rotors, in particular, may develop short circuits and there is a need for the operators to be aware of this situation. The manner in which shorted turns can occur in the rotors of generators and the difficulties associated with monitoring for such shorted turns are indicated. An online monitor which has been developed to solve this problem is described together with some operating experiences which have been learnt from the use of it
Keywords
automatic test equipment; automatic testing; computerised monitoring; electric breakdown; gas turbines; insulation testing; machine insulation; machine testing; microcomputer applications; power engineering computing; rotors; steam turbines; turbogenerators; electrical stress; gas turbines; insulation; mechanical stress; microcomputers; monitoring; operating experiences; rotor shorted turns; short circuits; steam turbines; turbine-generators;