  • Abstract
    High frequency (25-35 MHz), transthoracic, adult mouse echocardiography images sometimes exhibit low echogenecity in segments of the myocardium, resulting in degraded regional motion tracking. In this work, we performed high frequency (30 MHz) transthoracic ultrasound scanning on the left ventricle (LV) of normal C57BL/6 mice. Large-diameter microbubbles (range=2-8 mum, median~=5 mum) were used to enhance myocardial image signal via microbubbles lodging in the myocardial capillary bed [1]. Microbubbles produced an image intensity enhancement of 5-10 dB throughout the myocardium - especially in known signal dropout susceptible locations such as the septal wall. The motion analysis was performed using various filtering and tracking block size parameters, and the results were compared between analysis on microbubble-enhanced images and control echocardiographic images where no microbubbles were employed. The use of microbubbles allowed motion tracking without image pre-filtering and thus reduced the smoothing effect on motion tracking that filtering can cause. Motion tracking using smaller tracking block size (0.2 x 0.2 mm2 vs. 0.4 x 0.4 mm2) on microbubble- enhanced images yielded finer tracking accuracy and better resolution than when tracking was performed on control images. Microbubble enhancement also facilitated motion tracking measurements using "real-time" image sequences (requiring an acquisition lasting a few seconds) versus the previously preferred EKV data acquisition method (i.e., an ECG-gated EKV acquisition mode) that required 2-3 minutes.
  • Keywords
    bubbles; echocardiography; image enhancement; image motion analysis; image resolution; image sampling; image sequences; medical image processing; muscle; C57BL-6 mice; EKV data acquisition; echogenecity; frequency 25 MHz to 35 MHz; image intensity enhancement; image prefiltering; image resolution; image sequence; image smoothing; large-diameter microbubble; left ventricle; motion analysis; mouse echocardiography; myocardial capillary bed; myocardial motion tracking; septal wall; signal dropout susceptible location; transthoracic ultrasound scanning; Degradation; Echocardiography; Filtering; Frequency; Image segmentation; Mice; Motion analysis; Myocardium; Tracking; Ultrasonic imaging;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Ultrasonics Symposium, 2007. IEEE
  • Conference_Location
    New York, NY
  • ISSN
    1051-0117
  • Print_ISBN
    978-1-4244-1384-3
  • Electronic_ISBN
    1051-0117
  • Type

    conf

  • DOI
    10.1109/ULTSYM.2007.228
  • Filename
    4409801