Title :
Innovative solutions to control unintentional islanding on LV network with high penetration of distributed generation
Author :
Bufano, Vito ; D´Adamo, Christian ; D´Orazio, Luigi ; D´Orinzi, Cristiano
Author_Institution :
Enel Distribuzione S.p.A., Rome, Italy
Abstract :
During the last 3 years the Italian Distribution Network has experimented a dramatic increase of Distributed generation (DG) connected both at MV and LV levels, driven by incentive policies mainly to photovoltaic (PV) generators. The total amount of DG has reached the record level of 21 GW, out of which 4,2 GW connected to the LV network. Considering the high penetration of distributed generation the Transmission System Operator (TSO) asked additional technical requirements in the Grid Code to involve DG in the primary regulation during the frequency transient of the transmission grid. These new requirements have been reflected in a new issue of Italian LV connection standard (Italian Norm CEI 0-21) which foresees that all LV generators (synchronous, asynchronous or static) must be provided with a determined active Power - frequency regulation curve and must sustain the main network in the frequency range 47.5 - 51.5 Hz. These conditions may cause, under specific network conditions (e.g. MV ground fault) an uncontrolled network island. This paper focuses on the new connection criteria and on the possible solutions that Enel Distribuzione is experimenting to address the unintentional islanding on LV networks.
Keywords :
asynchronous generators; distributed power generation; frequency control; photovoltaic power systems; power control; power distribution control; power distribution economics; power grids; power system transients; power transmission control; power transmission economics; synchronous generators; DG; Enel Distribuzione; Italian LV connection standard; Italian Norm CEI 0-21 standard; Italian distribution network; LV asynchronous generator; LV static generator; LV synchronous generator; MV ground fault; MV network; PV generator; TSO; active power-frequency regulation curve; distributed generation; frequency 47.5 Hz to 51.5 Hz; frequency transient; grid code; incentive policy; photovoltaic generator; power 21 GW; power 4.2 GW; time 3 year; transmission grid; transmission system operator; unintentional islanding control;
Conference_Titel :
Electricity Distribution (CIRED 2013), 22nd International Conference and Exhibition on
Conference_Location :
Stockholm
Electronic_ISBN :
978-1-84919-732-8
DOI :
10.1049/cp.2013.0927