• DocumentCode
    2474194
  • Title

    Laboratory studies of slot discharges on stator bars

  • Author

    Lamarre, L. ; Jean, D. ; Nguyen, Duc Ngoc

  • Author_Institution
    IREQ, Varennes, Que., Canada
  • fYear
    2002
  • fDate
    2002
  • Firstpage
    490
  • Lastpage
    494
  • Abstract
    This paper is about experiments carried out on a laboratory stator mock-up comprising 6 stator bars installed in 3 different slots; some of the bars were intentionally damaged in order to reproduce slot discharges. Phase resolved partial discharge (PRPD) patterns, accompanied by simultaneous measurement of capacitance, loss tangent (tan δ) and harmonic analysis were recorded as a function of increasing voltage, from 0 to 16 kV, at steps of 500 V. Another set of results was taken after performing a repair procedure that consists in injecting s/c paint in the stator slots. Results presented here show how slot discharges affect capacitance, tan δ, Qmax, harmonics and PRPD patterns and how all of these quantities are further modified after the injection of s/c paint.
  • Keywords
    capacitance; harmonic analysis; machine insulation; partial discharges; stators; 0 to 16 kV; capacitance; harmonic analysis; laboratory stator mock-up; loss tangent; phase resolved partial discharge patterns; slot discharges; stator bars; Capacitance measurement; Harmonic analysis; Laboratories; Loss measurement; Paints; Partial discharge measurement; Partial discharges; Phase measurement; Stator bars; Voltage;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 2002 Annual Report Conference on
  • Print_ISBN
    0-7803-7502-5
  • Type

    conf

  • DOI
    10.1109/CEIDP.2002.1048841
  • Filename
    1048841