• DocumentCode
    2475573
  • Title

    Studies on static charging behaviour of transformer oils

  • Author

    Rajaraman, R. ; Mukherji, S. ; Suryanarayana, D. ; Adikesavulu, A.K. ; Murthy, T.S.R. ; Agashe, P.G.

  • Author_Institution
    Bharat Heavy Electricals Ltd., Hyderabad, India
  • fYear
    1993
  • fDate
    17-20 Oct 1993
  • Firstpage
    402
  • Lastpage
    407
  • Abstract
    Investigations on paraffinic oils are presented. Charge level measurements on a few paraffinic-based oils and a typical naphthenic-based oil are discussed. Most paraffinic oils were found to have high charge levels, which was attributed to higher ionic contamination and dominant chemical structure. While a charge suppressor reduced the charge levels of high charging oils, it had an adverse effect on other dielectric properties. However, its presence retarded ageing. Paraffinic oils from service transformers showed a significant deterioration in these properties compared to naphthenic oils
  • Keywords
    static electrification; transformer oil; ageing; charge suppressor; chemical structure; dielectric properties; high charge levels; ionic contamination; naphthenic-based oil; paraffinic oils; static charging behaviour; transformer oils; Charge measurement; Conductivity; Current measurement; Density measurement; Dielectric loss measurement; Dielectric losses; Electrical capacitance tomography; Electrostatic measurements; Oil insulation; Petroleum;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical Insulation and Dielectric Phenomena, 1993. Annual Report., Conference on
  • Conference_Location
    Pocono Manor, PA
  • Print_ISBN
    0-7803-0966-9
  • Type

    conf

  • DOI
    10.1109/CEIDP.1993.378939
  • Filename
    378939