Abstract :
According to the low yield of propylene existing in gas fractionation device due to higher C2 content in LPG, the factors affecting on LPG quality in the absorbing-stabilizing system were analyzed. Some technics such as optimization of operating condition and energy-efficient process were adopted to intensify the separation effect, offering the advice with lower C2 content (no more than 0.1 %χ) in LPG, fulfilling the technological requirements of double tower process for gas fractionation device.
Keywords :
petroleum; separation; C2; LPG quality; absorbing-stabilizing system; adaptability analysis; energy-efficient process; gas fractionation device; operating condition optimization; propylene; separation effect; Absorption; Chemical engineering; Chemical industry; FCC; Optimization; Petrochemicals; Petroleum; Absorbing-stabilizing; Absorption-desorption process; C2 content; LPG;