DocumentCode
2478578
Title
A novel electrical resistance tomography system based on C4D technique
Author
Wang, Baoliang ; Hu, Yuanyuan ; Ji, Haifeng ; Huang, Zhiyao ; Li, Haiqing
Author_Institution
Dept. of Control Sci. & Eng., Zhejiang Univ., Hangzhou, China
fYear
2012
fDate
13-16 May 2012
Firstpage
1929
Lastpage
1932
Abstract
For the traditional electrical resistance tomography systems, the contact between the electrodes and liquid may result in electrode corrosion, which limits the application of ERT in industry. In this paper, a new electrical resistance tomography system based on capacitively coupled contactless conductivity technique was developed. The conductivity distribution of liquid between electrodes can be measured without direct contact with the liquid. The data acquisition system is designed based on phase-sensitive demodulation method. Experiment results show that the conductivity distribution images can be reconstructed.
Keywords
computerised tomography; electrodes; image reconstruction; C4D technique; ERT; capacitively coupled contactless conductivity technique; conductivity distribution image reconstrcution; data acquisition system; electrical resistance tomography system; electrode corrosion; electrodes; phase-sensitive demodulation method; Conductivity; Contacts; Electrical resistance measurement; Electrodes; Image reconstruction; Resistance; Tomography; capacitively coupled contactless conductivity detection; data acquisition; electrical resistance tomography;
fLanguage
English
Publisher
ieee
Conference_Titel
Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International
Conference_Location
Graz
ISSN
1091-5281
Print_ISBN
978-1-4577-1773-4
Type
conf
DOI
10.1109/I2MTC.2012.6229290
Filename
6229290
Link To Document