Title :
A novel electrical resistance tomography system based on C4D technique
Author :
Wang, Baoliang ; Hu, Yuanyuan ; Ji, Haifeng ; Huang, Zhiyao ; Li, Haiqing
Author_Institution :
Dept. of Control Sci. & Eng., Zhejiang Univ., Hangzhou, China
Abstract :
For the traditional electrical resistance tomography systems, the contact between the electrodes and liquid may result in electrode corrosion, which limits the application of ERT in industry. In this paper, a new electrical resistance tomography system based on capacitively coupled contactless conductivity technique was developed. The conductivity distribution of liquid between electrodes can be measured without direct contact with the liquid. The data acquisition system is designed based on phase-sensitive demodulation method. Experiment results show that the conductivity distribution images can be reconstructed.
Keywords :
computerised tomography; electrodes; image reconstruction; C4D technique; ERT; capacitively coupled contactless conductivity technique; conductivity distribution image reconstrcution; data acquisition system; electrical resistance tomography system; electrode corrosion; electrodes; phase-sensitive demodulation method; Conductivity; Contacts; Electrical resistance measurement; Electrodes; Image reconstruction; Resistance; Tomography; capacitively coupled contactless conductivity detection; data acquisition; electrical resistance tomography;
Conference_Titel :
Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International
Conference_Location :
Graz
Print_ISBN :
978-1-4577-1773-4
DOI :
10.1109/I2MTC.2012.6229290