DocumentCode :
2479507
Title :
Results on the Power Quality of French and Italian 2×25 kV 50 Hz railways
Author :
Mariscotti, A.
Author_Institution :
DYNATECH, Univ. of Genova, Genova, Italy
fYear :
2012
fDate :
13-16 May 2012
Firstpage :
1400
Lastpage :
1405
Abstract :
The pantograph voltage and current waveforms recorded across the Italian and French high speed railway lines (both Autotransformer 2×25 kV 50 Hz systems) are analyzed to estimate some Power Quality indexes: harmonic spectra, harmonic distortion, displacement factor and fundamental component, in various load conditions. These indexes, that define the electrical interface between the rolling stock and the power supply, are all required by the technical standards for interoperability.
Keywords :
autotransformers; open systems; power supply quality; railways; French railways; Italian railways; autotransformer; current waveforms; displacement factor; electrical interface; frequency 50 Hz; fundamental component; harmonic distortion; harmonic spectra; high speed railway lines; interoperability; pantograph voltage; power quality; power supply; rolling stock; technical standards; voltage 25 kV; Harmonic analysis; Indexes; Power quality; Rail transportation; Standards; Transient analysis; Guideway transportation systems; Power quality; Spectral analysis;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Instrumentation and Measurement Technology Conference (I2MTC), 2012 IEEE International
Conference_Location :
Graz
ISSN :
1091-5281
Print_ISBN :
978-1-4577-1773-4
Type :
conf
DOI :
10.1109/I2MTC.2012.6229341
Filename :
6229341
Link To Document :
بازگشت