DocumentCode
2480552
Title
Potential of digital holography in sprays measurement
Author
Yang, Yan ; Kang, Bo-seon
Author_Institution
Dept. of Mech. Eng. Syst., Chongqing Inst. of Technol., Chongqing
fYear
2008
fDate
25-27 June 2008
Firstpage
1702
Lastpage
1707
Abstract
This study presents in-line digital particle holography and its application to spray droplets to measure the characteristics of spray droplets. Several important parameters at the time of hologram recording such as the pixel number of holograms, the object distance, and the part of laser beam used were verified. The optimum values of all these parameters are obtained by either numerical simulation of holograms or experiments. Using these optimum parameters, two digital spray holograms in a short time interval are recorded with the synchronization system for the time control. The three dimensional droplet velocities and several important features of spray droplets can be easily located.
Keywords
computer vision; drops; flow measurement; flow visualisation; holography; measurement by laser beam; mechanical engineering computing; digital holography; hologram recording; inline digital particle holography; object distance; spray droplets; sprays measurement; synchronization system; Charge coupled devices; Holographic optical components; Holography; Image reconstruction; Laser beams; Mechanical variables measurement; Optical films; Optical recording; Particle measurements; Spraying; Digital holography; Focal plane; Sprays;
fLanguage
English
Publisher
ieee
Conference_Titel
Intelligent Control and Automation, 2008. WCICA 2008. 7th World Congress on
Conference_Location
Chongqing
Print_ISBN
978-1-4244-2113-8
Electronic_ISBN
978-1-4244-2114-5
Type
conf
DOI
10.1109/WCICA.2008.4593176
Filename
4593176
Link To Document