• DocumentCode
    2483346
  • Title

    Absolute calibration of a 100 KV DC divider

  • Author

    Bergman, A.

  • Author_Institution
    Swedish Nat. Testing & Res. Inst., Boras, Sweden
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    565
  • Lastpage
    566
  • Abstract
    An absolute determination of the ratio of a 100 kV DC divider has been made. A new Zener device that has recently become available has been used in a step-up mode to obtain the divider ratio. The uncertainty of the determination is 5.5 ppm.
  • Keywords
    Zener diodes; calibration; high-voltage techniques; voltage dividers; voltage measurement; 100 kV; DC divider; Zener device; absolute calibration; divider ratio; step-up mode; uncertainty; Calibration; Current measurement; Diodes; Dynamic voltage scaling; Laboratories; Low voltage; Performance evaluation; Strips; Testing; Voltage measurement;