DocumentCode
2483346
Title
Absolute calibration of a 100 KV DC divider
Author
Bergman, A.
Author_Institution
Swedish Nat. Testing & Res. Inst., Boras, Sweden
fYear
1996
fDate
17-21 June 1996
Firstpage
565
Lastpage
566
Abstract
An absolute determination of the ratio of a 100 kV DC divider has been made. A new Zener device that has recently become available has been used in a step-up mode to obtain the divider ratio. The uncertainty of the determination is 5.5 ppm.
Keywords
Zener diodes; calibration; high-voltage techniques; voltage dividers; voltage measurement; 100 kV; DC divider; Zener device; absolute calibration; divider ratio; step-up mode; uncertainty; Calibration; Current measurement; Diodes; Dynamic voltage scaling; Laboratories; Low voltage; Performance evaluation; Strips; Testing; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location
Braunschweig, Germany
Print_ISBN
0-7803-3376-4
Type
conf
DOI
10.1109/CPEM.1996.547351
Filename
547351
Link To Document