DocumentCode
2483714
Title
Measurements and simulations of corona currents due to triangular voltages in large scale coaxial geometry
Author
Schiessling, Joachim ; Hjortstam, Olof ; Gäfvert, Uno ; Saltzer, Markus ; Serdyuk, Yuriy V.
Author_Institution
ABB Corp. Res., Västeras, Sweden
fYear
2012
fDate
14-17 Oct. 2012
Firstpage
357
Lastpage
360
Abstract
Corona currents in air measured in a large scale coaxial geometry (douter = 1 m, dinner = 0.26 mm), under both DC and AC voltages of a triangular shape with frequencies in the range (1-50) Hz are analyzed. A computational model describing dynamics of positive and negative ionic charges is employed to examine the results of the measurements. The performed simulations show a good overall agreement with the experimental data.
Keywords
corona; corona current measurements; corona current simulation; frequency 1 Hz to 50 Hz; large scale coaxial geometry; negative ionic charges; size 0.26 mm; size 1 m; triangular voltages; Atmospheric modeling; Computational modeling; Corona; Current measurement; Electrodes; Ions; Voltage measurement;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena (CEIDP), 2012 Annual Report Conference on
Conference_Location
Montreal, QC
ISSN
0084-9162
Print_ISBN
978-1-4673-1253-0
Electronic_ISBN
0084-9162
Type
conf
DOI
10.1109/CEIDP.2012.6378794
Filename
6378794
Link To Document