• DocumentCode
    2484312
  • Title

    Dynamic response of variable frequency drives in electrical submersible pump systems

  • Author

    Liang, Xiaodong ; Ilochonwu, Obinna ; Adedun, Rotimi

  • Author_Institution
    Edmonton Product Center, Schlumberger, Edmonton, AB, Canada
  • fYear
    2012
  • fDate
    20-24 May 2012
  • Firstpage
    1
  • Lastpage
    11
  • Abstract
    Dynamic response of variable frequency drives (VFD) during short-circuit faults for the electrical submersible pump (ESP) systems are investigated in this paper. Because of special characteristics of VFDs and ESP systems, the dynamic response of the drive during faults is quite different from that of general power distribution systems. The simulation conducted by PSCAD provides detailed and clear pictures how the drive and the ESP motor will react for each specific fault.
  • Keywords
    dynamic response; induction motor drives; power distribution faults; pumps; short-circuit currents; variable speed drives; ESP motor; ESP systems; PSCAD simulation; VFD; dynamic response; electrical submersible pump motor systems; power distribution systems; short-circuit faults; two-pole three-phase induction motor; variable frequency drives; Inverters; PSCAD; TV; Dynamic response; short circuit fault; single-phased operation mode; variable frequency drives;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Industrial & Commercial Power Systems Technical Conference (I&CPS), 2012 IEEE/IAS 48th
  • Conference_Location
    Louisville, KY
  • ISSN
    2158-4893
  • Print_ISBN
    978-1-4673-0652-2
  • Type

    conf

  • DOI
    10.1109/ICPS.2012.6229603
  • Filename
    6229603