• DocumentCode
    2484532
  • Title

    Wide-band inductive voltage divider for ac voltage calibrations

  • Author

    Skubis, T. ; Klonz, M.

  • Author_Institution
    Katedra Metrol. i Aut. Elektrot, Gliwice, Poland
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    576
  • Lastpage
    577
  • Abstract
    The paper describes an inductive voltage divider developed for fitting the low-voltage range measuring instruments to the ac-dc transfer standards for voltages of 1 V. The divider, the associated circuit and the calibration procedure allow one to compare the standard and unknown ac instrument at 1:10 ratio in the frequency band from 1 kHz to 1 MHz. The construction and uncertainty budget are given.
  • Keywords
    calibration; inductors; measurement errors; measurement standards; voltage dividers; voltage measurement; 1 V; 1 kHz to 1 MHz; AC voltage calibrations; AC-DC transfer standards; construction; load error measurement; low-voltage range measuring instruments; ratio winding; screening; toroidal magnetic cores; two-stage divider; uncertainty budget; wide-band inductive voltage divider; Calibration; Instruments; Magnetic cores; Magnetic flux; Magnetic separation; Measurement standards; Sockets; Toroidal magnetic fields; Voltage; Wideband;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547357
  • Filename
    547357