• DocumentCode
    2484671
  • Title

    Characterization of an air jet haptic lump display

  • Author

    Bianchi, Matteo ; Gwilliam, James C. ; Degirmenci, Alperen ; Okamura, Allison M.

  • Author_Institution
    Interdept. Res. Center E. Pi-aggio, Univ. of Pisa, Pisa, Italy
  • fYear
    2011
  • fDate
    Aug. 30 2011-Sept. 3 2011
  • Firstpage
    3467
  • Lastpage
    3470
  • Abstract
    During manual palpation, clinicians rely on distributed tactile information to identify and localize hard lumps embedded in soft tissue. The development of tactile feedback systems to enhance palpation using robot-assisted minimally invasive surgery (RMIS) systems is challenging due to size and weight constraints, motivating a pneumatic actuation strategy. Recently, an air jet approach has been proposed for generating a lump percept. We use this technique to direct a thin stream of air through an aperture directly on the finger pad, which indents the skin in a hemispherical manner, producing a compelling lump percept. We hypothesize that the perceived parameters of the lump (e.g. size and stiffness) can be controlled by jointly adjusting air pressure and the aperture size through which air escapes. In this work, we investigate how these control variables interact to affect perceived pressure on the finger pad. First, we used a capacitive tactile sensor array to measure the effect of aperture size on output pressure, and found that peak output pressure increases with aperture size. Second, we performed a psychophysical experiment for each aperture size to determine the just noticeable difference (JND) of air pressure on the finger pad. Subject-averaged pressure JND values ranged from 19.4-24.7 kPa, with no statistical differences observed between aperture sizes. The aperture-pressure relationship and the pressure JND values will be fundamental for future display control.
  • Keywords
    air; biomechanics; biomedical measurement; skin; tactile sensors; air jet haptic lump display; air pressure; air thin stream; aperture-pressure relationship; capacitive tactile sensor array; finger pad; hemispherical manner; just noticeable difference; lump percept; manual palpation; output pressure; pressure 19.4 kPa to 24.7 kPa; psychophysical experiment; skin; subject-averaged pressure JND values; Apertures; Arrays; Haptic interfaces; Pressure measurement; Size measurement; Tactile sensors; Air; Humans; Psychophysics; Robotics; Skin; Touch;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Engineering in Medicine and Biology Society, EMBC, 2011 Annual International Conference of the IEEE
  • Conference_Location
    Boston, MA
  • ISSN
    1557-170X
  • Print_ISBN
    978-1-4244-4121-1
  • Electronic_ISBN
    1557-170X
  • Type

    conf

  • DOI
    10.1109/IEMBS.2011.6090937
  • Filename
    6090937