DocumentCode
2484903
Title
Improvements in the NRC ac-dc transfer capabilities
Author
Clark, R.F. ; Filipski, P.S. ; Paulusse, D.C.
Author_Institution
Inst. for Nat. Meas. Stand., Nat. Res. Council of Canada, Ottawa, Ont., Canada
fYear
1996
fDate
17-21 June 1996
Firstpage
580
Lastpage
581
Abstract
The paper describes upgrading of NRC ac-dc transfer facilities, test results using new calorimetric TVC reference standards as well as redetermination of ac-dc transfer for voltage measurement over the 10 Hz-30 MHz frequency range.
Keywords
calorimeters; comparators (circuits); measurement standards; voltage measurement; 10 Hz to 30 MHz; NRC ac-dc transfer; National Research Council; calorimetric TVC reference standards; thermal voltage converter; voltage measurement; Calibration; Computer errors; Councils; Frequency conversion; Resistors; Switching converters; Temperature; Testing; Uncertainty; Voltage;