Title :
Maximum levels inside an electromagnetic shielded cavity
Author_Institution :
Inf. Syst., Swedish Defence Res. Agency FOI, Linköping, Sweden
Abstract :
We present analytic expressions to quickly calculate the maximum electric field and power levels inside an electromagnetic shielded cavity. Typical maximum values are 9-11 dB larger than the corresponding average values. The method is applicable to both worst case estimates in e.g. an avionics bay, as well as to calculate the test quantity when performing a radiated susceptibility test in the reverberation chamber.
Keywords :
electric fields; electromagnetic shielding; reverberation chambers; electric field; electromagnetic shielded cavity; power level; radiated susceptibility test; reverberation chamber; Cavity resonators; Electric fields; Random variables; Reverberation chamber; Uncertainty;
Conference_Titel :
Electromagnetic Compatibility (EMC), 2010 IEEE International Symposium on
Conference_Location :
Fort Lauderdale, FL
Print_ISBN :
978-1-4244-6305-3
DOI :
10.1109/ISEMC.2010.5711261