DocumentCode
2486112
Title
Aging investigation of low-voltage cable insulation used in nuclear power plants
Author
Verardi, L. ; Fabiani, D. ; Montanari, G.C. ; Gedde, U.W. ; Linde, E.
Author_Institution
Dipt. di Ing. Elettr., Univ. di Bologna, Bologna, Italy
fYear
2012
fDate
14-17 Oct. 2012
Firstpage
851
Lastpage
854
Abstract
This paper presents some preliminary results of mechanical and electrical tests carried out on CSPE/EPDM polymer insulation used in low-voltage nuclear power plant cables. The whole cables were exposed to operation stresses for 30 years, then the inner low-voltage insulations have been aged further in the lab under thermal and radiation stresses. Electrical measurements are performed on aged cable specimens using dielectric spectroscopy. Mechanical properties are investigated through tensile testing, i.e. elongation at break and Young´s modulus. These properties are aging markers commonly used to assess the conditions of low-voltage cables operating inside nuclear power plants containment area. First results have shown a significant increase of the real and imaginary parts of dielectric permittivity, especially at low frequencies, which can be correlated to bulk insulation aging. This paper represents only a part of a more extended work, which aims at identifying electrical aging markers able to correlate electrical and mechanical properties with aging.
Keywords
Young´s modulus; ageing; elongation; insulation testing; nuclear power stations; organic insulating materials; permittivity; power cable insulation; power cable testing; tensile testing; thermal stresses; CSPE/EPDM polymer insulation; Young´s modulus; aged cable specimens; bulk insulation aging; cable insulation aging; dielectric permittivity; dielectric spectroscopy; electrical aging marker identification; electrical measurements; electrical tests; elongation; low-voltage cable insulation; low-voltage nuclear power plant cables; mechanical properties; mechanical tests; nuclear power plant containment; operation stresses; radiation stresses; tensile testing; thermal stresses; Accelerated aging; Cable insulation; Cable shielding; Dielectrics; Mechanical factors; Permittivity;
fLanguage
English
Publisher
ieee
Conference_Titel
Electrical Insulation and Dielectric Phenomena (CEIDP), 2012 Annual Report Conference on
Conference_Location
Montreal, QC
ISSN
0084-9162
Print_ISBN
978-1-4673-1253-0
Electronic_ISBN
0084-9162
Type
conf
DOI
10.1109/CEIDP.2012.6378914
Filename
6378914
Link To Document