• DocumentCode
    2488350
  • Title

    Measurement and reduction of alignment errors of the NIST watt experiment

  • Author

    Gillespie, A. ; Fujii, K. ; Newell, D. ; Olsen, P.T. ; Picard, A. ; Steiner, R. ; Stenbakken, G. ; Williams, E.

  • Author_Institution
    Nat. Inst. of Stand. & Technol., Gaithersburg, MD, USA
  • fYear
    1996
  • fDate
    17-21 June 1996
  • Firstpage
    614
  • Lastpage
    615
  • Abstract
    The effects of uncertainties in the alignment of the NIST watt balance with local gravity and the magnetic field of the balance have been analyzed, and techniques for measuring all misalignment parameters have been developed. The systematic uncertainty in the watt measurement due to alignment has been reduced to 0.04 /spl mu/W/W.
  • Keywords
    balances; inductors; light interferometry; mass measurement; measurement by laser beam; measurement errors; measurement standards; power measurement; weighing; NIST watt balance; alignment errors; induction loop; kilogram monitoring; local gravity; magnetic field; mass standard; misalignment parameters; reference laser beams; systematic uncertainty; uncertainties; watt measurement; Electric variables measurement; Force measurement; Interferometers; Laser beams; Magnetic field measurement; NIST; Position measurement; Velocity measurement; Voltage measurement; Wheels;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Precision Electromagnetic Measurements Digest, 1996 Conference on
  • Conference_Location
    Braunschweig, Germany
  • Print_ISBN
    0-7803-3376-4
  • Type

    conf

  • DOI
    10.1109/CPEM.1996.547376
  • Filename
    547376