• DocumentCode
    2492113
  • Title

    Numerical Electromagnetic Analysis of Lightning Current in Elevated Strike Objects

  • Author

    Hossain, Md Faruque ; Yusuf, Md Salah Uddin ; Goni, Md Osman

  • Author_Institution
    Dept. of Electron. & Commun. Eng., KUET, Khulna
  • fYear
    2006
  • fDate
    19-21 Dec. 2006
  • Firstpage
    548
  • Lastpage
    551
  • Abstract
    In this paper, an analysis of electric and magnetic fields radiated by lightning first and subsequent return strokes to tall towers using Numerical Electromagnetic Code (NEC-2) is presented. The advantage of the analysis using NEC-2 is that it can accurately compute the current distribution along a conductor system by the method of moments. It is shown that the presence of a tower tends, in general, to increase substantially the electric and magnetic field peaks. The presented results are shown to be consistent with the measured current in lightning strokes to the CN Tower and of the associated electromagnetic fields measured 2 km away.
  • Keywords
    current distribution; electric current measurement; electric field measurement; electric fields; lightning; magnetic field measurement; magnetic fields; method of moments; current distribution; elevated strike objects; lightning current; method of moments; numerical electromagnetic analysis; Current measurement; Electromagnetic analysis; Electromagnetic fields; Electromagnetic measurements; Electromagnetic radiation; Lightning; Magnetic analysis; Magnetic field measurement; Magnetic fields; Poles and towers;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Electrical and Computer Engineering, 2006. ICECE '06. International Conference on
  • Conference_Location
    Dhaka
  • Print_ISBN
    98432-3814-1
  • Type

    conf

  • DOI
    10.1109/ICECE.2006.355690
  • Filename
    4178526