DocumentCode
2492710
Title
Procedure to calibrate a network-analyzer for the measurement of voltages at any impedance
Author
Wilken, L.
Author_Institution
Eulenbaumstrasse 253, Bochum, Germany
fYear
1996
fDate
17-21 June 1996
Abstract
A calibration procedure for network analyzes was developed, which makes you able to measure the absolute value of the voltage a the current at the calibration plane or the power propagating towards the device under test. These measurements are independent of the impedance at the calibration plane.
Keywords
calibration; electric current measurement; network analysers; power measurement; voltage measurement; calibration; current measurement; measurement of voltages; network-analyzer; power measurement; Impedance measurement; Voltage;
fLanguage
English
Publisher
ieee
Conference_Titel
Precision Electromagnetic Measurements Digest, 1996 Conference on
Conference_Location
Braunschweig, Germany
Print_ISBN
0-7803-3376-4
Type
conf
DOI
10.1109/CPEM.1996.547414
Filename
547414
Link To Document