Title :
Bioimpedance spectroscopy for cell characterization in the 50Hz-5MHz frequency range
Author :
Margo, Cédric ; Prado, Juan ; Kouider, Mourad ; Rouane, Amar ; Nadi, Mustapha
Author_Institution :
Lab. d´´Instrum. Electronique de Nancy
Abstract :
This paper presents impedance spectroscopy measurements based on auto-balancing bridge method (50Hz-5MHz) on a single Xenopeus Oocyte cell with a two electrodes sensor chip. It has been seen that the presence of the cell in the sensor modify frequency behavior of impedance. In addition, electric modelling of the sensor with and without cell was achieved using finite elements method and showed influence of cytoplasm conductivity
Keywords :
bioelectric phenomena; biological techniques; biomedical electrodes; biosensors; cellular biophysics; finite element analysis; 50 to 5000000 Hz; Finite elements method; Hz frequency range; Xenopeus Oocyte cell; auto balancing bridge method; bioimpedance spectroscopy; cell characterization; cytoplasm conductivity; electrodes sensor chip; Bioimpedance; Biosensors; Bridges; Electrochemical impedance spectroscopy; Electrodes; Finite element methods; Frequency; Impedance measurement; Semiconductor device measurement; Sensor phenomena and characterization;
Conference_Titel :
Research in Microelectronics and Electronics 2006, Ph. D.
Conference_Location :
Otranto
Print_ISBN :
1-4244-0157-7
DOI :
10.1109/RME.2006.1689988