Title :
Partial discharge testing of motor and generator windings: an absolute or a comparison test?
Author :
Stone, Greg C. ; Kantardziski, Peter
Author_Institution :
Iris Power Eng. Inc., Etobicoke, Ont., Canada
Abstract :
Partial discharge (PD) tests on operating motors and generators are now widely used around the world to assess the condition of the stator winding insulation. Data is presented which shows that the calibration into picoCoulumbs can yield misleading interpretations. The reasons for this are discussed. The conclusion is that with present technology, PD testing of stator windings can only be comparative
Keywords :
calibration; insulation testing; machine insulation; machine testing; partial discharge measurement; stators; calibration; generator; motor; partial discharge testing; stator winding insulation; Antenna measurements; Capacitance measurement; Electric variables measurement; Electrons; Frequency; Insulation testing; Partial discharges; Power transformer insulation; Pulse measurements; Stator windings;
Conference_Titel :
Electrical Insulating Materials, 1998. Proceedings of 1998 International Symposium on
Conference_Location :
Toyohashi
Print_ISBN :
4-88686-050-8
DOI :
10.1109/ISEIM.1998.741685