DocumentCode
25014
Title
Accurate Wavelength Calibration Method for Spectrometer Using Low Coherence Interferometry
Author
Ji-Hyun Kim ; Jae-Ho Han ; Jichai Jeong
Author_Institution
Dept. of Brain & Cognitive Eng., Korea Univ., Seoul, South Korea
Volume
33
Issue
16
fYear
2015
fDate
Aug.15, 15 2015
Firstpage
3413
Lastpage
3418
Abstract
Dispersive spectrometers are subject to wavelength dispersion errors due to aberration, ruling errors, etc. Thus, their calibration forms an integral aspect of their usage. In this context, we present an interferometric wavelength calibration method for calibrating dispersive spectrometers. The calibration system is based on low coherence interferometry. By analyzing the sinusoidal interference patterns that are modulated in a spectrum, we determine the distribution of wavelengths in a spectrometer using the zero-crossing detection. The spectral sampling interval of the spectrometer is estimated by determining the sampling interval in the z-domain. Assigning only one wavelength to the corresponding camera pixel using a narrowband light source allows the determination of entire wavelengths accurately. We use the information of the wavelength distribution, spectral sampling interval, and wavelength data to achieve accurate calibration. Our experimental results show that the proposed method calibrates wavelength more accurately than conventional methods, since the interferometric calibration can reduce the wavelength fitting error arising from extrapolation. Moreover, the proposed calibration method can reduce the side-lobe amplitude maximally by 4.8 dB when applied to OCT imaging. We believe that our findings can significantly aid in the development of spectrometry.
Keywords
calibration; infrared spectrometers; light coherence; light interference; light interferometry; optical dispersion; optical modulation; optical tomography; OCT imaging; aberration; camera pixel; dispersive spectrometers; extrapolation; interferometric wavelength calibration method; low coherence interferometry; narrowband light source; ruling errors; side-lobe amplitude; sinusoidal interference patterns; spectral sampling interval; wavelength dispersion errors; wavelength distribution; wavelength fitting error; z-domain; zero-crossing detection; Calibration; Coherence; Fitting; Indexes; Light sources; Mirrors; Optical interferometry; Biomedical imaging; Calibration; Optical imaging; Spectroscopy; calibration; optical imaging; optical interferometry; spectroscopy;
fLanguage
English
Journal_Title
Lightwave Technology, Journal of
Publisher
ieee
ISSN
0733-8724
Type
jour
DOI
10.1109/JLT.2015.2393881
Filename
7014224
Link To Document