Title :
Measurements of transfer impedance with the line injection method on cables and connectors
Author :
Bluhm, M. ; Peroglio, E. ; Pierucci, G. ; Squizzato, V. ; Zich, R.E.
Author_Institution :
W.L. GORE Nordring, Pleinfeld, Germany
Abstract :
In an electronic system the connection cables and the relevant connectors have been recognized as one of the main causes of interference in different apparatus. Different methods are used to evaluate the shielding effectiveness of cables and connectors. In this paper the method of the line injection is addressed and the results of measurements on a number of samples of cables and connectors are presented. The measurements on the same samples were carried out in two different laboratories in order to assure the reliability of the method
Keywords :
cable shielding; cable testing; coaxial cables; electric connectors; electric immittance measurement; electromagnetic interference; electromagnetic shielding; balanced shielded cables; coaxial cables; connectors; electronic system; interference; laboratories; line injection method; reliability; shielding effectiveness; transfer impedance measurements; Coaxial cables; Conductors; Connectors; Coupling circuits; Impedance measurement; Interference; Laboratories; Magnetosphere; Transmission line measurements; Voltage;
Conference_Titel :
Electromagnetic Compatibility, 2000. IEEE International Symposium on
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-5677-2
DOI :
10.1109/ISEMC.2000.874688