DocumentCode
2501739
Title
Measuring the shielding effectiveness of coaxial cables using a reverberation chamber
Author
Godfrey, Emily A. ; Kousky, Justin T.
Author_Institution
Naval Surface Warfare Center, Dahlgren, VA, USA
Volume
2
fYear
2000
fDate
2000
Firstpage
627
Abstract
The measurement of shielding effectiveness of coaxial cables is often limited by the dynamic range of the measurement system. This paper discusses the methods used to establish a dynamic range of 150 dB at 1 GHz, and 120 dB at 18 GHz, using a small reverberation chamber to measure the shielding effectiveness of coaxial cables. The chamber used had dimensions of 1.8×1.2×0.8 m
Keywords
cable shielding; cable testing; coaxial cables; electromagnetic shielding; reverberation chambers; 0.8 m; 1 GHz; 1.2 m; 1.8 m; 18 GHz; chamber dimensions; coaxial cables; dynamic range; measurement system; reverberation chamber; shielding effectiveness measurement; Aluminum; Antenna measurements; Coaxial cables; Connectors; Dynamic range; Radio frequency; Reverberation chamber; Steel; Testing; Wool;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility, 2000. IEEE International Symposium on
Conference_Location
Washington, DC
Print_ISBN
0-7803-5677-2
Type
conf
DOI
10.1109/ISEMC.2000.874693
Filename
874693