DocumentCode :
2502695
Title :
Correlation test among EMI measurement sites using a comb generator
Author :
Osabe, Kunihiro ; Komatsuzaki, Takeshi ; Tamara, K.
Author_Institution :
Matsushita Commun. Ind. Co. Ltd., Yokohama, Japan
Volume :
2
fYear :
2000
fDate :
2000
Firstpage :
945
Abstract :
VCCI had considered that a major reason why we cannot get correlated data on the radiated interference (especially one from the power cord in the frequency range up to 300 MHz) among different measurement sites might be that the characteristics and environment of the power lines to the EUT (equipment under test) are different at each site. Therefore, we performed a correlation test at eight EMI measurement sites using a comb generator as an EUT to whose output terminal a cable was connected, based on an assumption that the correlation among sites would be improved if the common-mode impedance of the power lines is specified at each site. The test results show that the correlation among sites was improved when the common-mode impedance of the power lines was constant. But, the actual laying route and position of the power cord had some influence in the frequency range of 60 to 80 MHz, and the effect of the constant common-mode impedance was less clear than one in the other frequency ranges. Also, the correlation among 14 sites using an actual EUT was improved comparing the standard deviations with the current CISPR22 measurement conditions, when the common-mode impedance of the power lines to an EUT was constant
Keywords :
anechoic chambers (electromagnetic); correlation methods; electric generators; electromagnetic interference; power cables; 300 MHz; 60 to 80 MHz; CISPR22 measurement conditions; EMI; EMI measurement sites; EUT; OATS; VCCI; comb generator; common-mode impedance; correlated data; correlation test; equipment under test; frequency range; open-area test site; output terminal; power cable; power cord laying route; power cord position; power lines; radiated interference; semianechoic chambers; standard deviations; test results; Antenna measurements; Electric variables measurement; Electromagnetic interference; Frequency measurement; Impedance; Measurement standards; Plugs; Power generation; Power measurement; Testing;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Electromagnetic Compatibility, 2000. IEEE International Symposium on
Conference_Location :
Washington, DC
Print_ISBN :
0-7803-5677-2
Type :
conf
DOI :
10.1109/ISEMC.2000.874750
Filename :
874750