DocumentCode :
2504273
Title :
Digital Marker Tracing Combined with Center-of-Mass Algorithm in Analyzing Viscoelasticity Characteristic of Lumbosacroiliac Complex
Author :
Lv, Haoxuan ; Cheng, Liming ; Yu, Yan ; Jia, Yongwei
Author_Institution :
Dept. of Orfhopeadics, Tongji Univ., Shanghai, China
fYear :
2009
fDate :
11-13 June 2009
Firstpage :
1
Lastpage :
3
Abstract :
The objective of this study is to analyze stability and viscoelasticity of lunibosacroiliac complex and to provide data to relative biomechanical analysis and clinic pelvic operations. Six cadaveric specimens of the third lumbar vertebra to the proximal 1/3 part of femur were used in present study, fixed on special bench. The specimens had no structural abnormality and all the soft tissues were dissected, reserving the hip joint capsules and the ligaments of the pelvic ring and floor. Markers with black dots against white background were used to mark the key points of the pelvis. Axial loadings from the proximal lumbar were applied by MTS in the gradient of ON to 500 N. Images of the front and lateral views were obtained using two CCD cameras.Using image J software, we calculated relative falling distance of L5, abducent degree of pelvic coronal plane and rotational degree of pelvic vertical plane by measuring the marker´s movement. Under a vertical load of 500 N, the average relative falling distance of L5 was (1.157plusmn0.794) mm, the average abducent degree of pelvic coronal plane was (0.370plusmn0.260)deg and the average rotational degree of pelvic vertical plane was (1.051plusmn1.728)deg. Common pelvic specimen has satisfactory stability and shows viscoelastic property of lumbosacroiliac complex by using digital marker tracing method combined with the center-of-mass algorithm.
Keywords :
CCD image sensors; biomechanics; bone; medical image processing; orthopaedics; viscoelasticity; CCD cameras; biomechanical analysis; center-of-mass algorithm; clinic pelvic operation; digital marker tracing; hip joint capsule; image J software; lumbar vertebra; lumbosacroiliac complex; markers movement measurement; medical imaging; viscoelasticity; Algorithm design and analysis; Biological tissues; Charge coupled devices; Elasticity; Hip; Ligaments; Motion measurement; Pelvis; Stability analysis; Viscosity;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Bioinformatics and Biomedical Engineering , 2009. ICBBE 2009. 3rd International Conference on
Conference_Location :
Beijing
Print_ISBN :
978-1-4244-2901-1
Electronic_ISBN :
978-1-4244-2902-8
Type :
conf
DOI :
10.1109/ICBBE.2009.5162642
Filename :
5162642
Link To Document :
بازگشت