Thermal mass characterization of a server at different fan speeds
Author :
Ibrahim, Mahmoud ; Shrivastava, Saurabh ; Sammakia, Bahgat ; Ghose, Kanad
Author_Institution :
Panduit Corp., Tinley Park, IL, USA
fYear :
2012
fDate :
May 30 2012-June 1 2012
Firstpage :
457
Lastpage :
465
Abstract :
Dynamic cooling has been proposed as one approach for enhancing the energy efficiency of data center facilities. It involves using sensors to closely monitor the data center environment with time and making real time decisions on how to allocate the cooling resources based on the location of hotspots and concentration of workloads. In order to effectively implement this approach, it is good to know the transient thermal response of the various systems comprising the data center must be determined, which is a function of thermal mass. Not only is thermal mass important in dynamic cooling, it also plays a major role in the temperature rise of a data center during power failure. A previous study concentrated on characterizing the thermal mass of a 2 RU server by running the server at different powers and a fixed fan speed. The fixed fan speed corresponds to one specific heat transfer coefficient value. This study is a continuation to the previous work, where the server fan speed is varied to deduce the change in heat transfer coefficient at different airflow rates. As expected, the heat transfer coefficient increases as the server airflow rate increases. The average thermal mass value obtained for the 2 RU server in this study was 12 kJ/K. A method of adopting the compact model developed in this study into a Computational Fluid Dynamics (CFD) code is proposed to cut down on the computational time of transient analysis.
Keywords :
computational fluid dynamics; computer centres; cooling; decision making; energy conservation; fans; heat transfer; network servers; resource allocation; thermal analysis; transient analysis; transient response; CFD code; RU server; computational fluid dynamics; cooling resource allocation; data center facility; dynamic cooling; energy efficiency; fixed fan speed; power failure; real time decision making; sensors; server airflow rate; specific heat transfer coefficient value; temperature rise; thermal mass characterization; transient analysis; transient thermal response; Analytical models; Atmospheric modeling; Cooling; Heat transfer; Servers; Temperature measurement; Transient analysis; Data centers; compact models; dynamic; heat transfer coefficient; thermal mass; transient;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
Thermal and Thermomechanical Phenomena in Electronic Systems (ITherm), 2012 13th IEEE Intersociety Conference on
Conference_Location :
San Diego, CA
ISSN :
1087-9870
Print_ISBN :
978-1-4244-9533-7
Electronic_ISBN :
1087-9870
Type :
conf
DOI :
10.1109/ITHERM.2012.6231467
Filename :
6231467
Link To Document :
بازگشت