DocumentCode
2508300
Title
Experimental Study on Sterilization Performance of Compound Air Cleaner
Author
Wang, Leilei ; You, Shijun ; Lu, Shichang
Author_Institution
Sch. of Environ. Sci. & Technol., Tianjin Univ., Tianjin, China
fYear
2009
fDate
11-13 June 2009
Firstpage
1
Lastpage
4
Abstract
The split type air conditioner has less control of indoor biological particles, volatile organic compounds and other pollutants. A compound air cleaner representing and photo catalytic purifying effect is equipped to the residential conditioner. The sterilization performance of the air cleaning conditioner is tested in an office room using airborne microbe Colony Forming Unit (CFU) index. It is observed that this type of air cleaning conditioner could reduce the microbe count in the air rapidly to provide healthy indoor environment. More investigation is needed to study the sterilization performance contributed by electrostatic filter and photo catalyst respectively.
Keywords
air cleaners; air conditioning; air pollution measurement; biological specimen preparation; catalysis; electrostatics; microorganisms; photochemistry; Colony Forming Unit; compound air cleaner; electrostatic filter; photocatalysis; purifying effect; sterilization; Air cleaners; Air pollution; Electrostatic precipitators; Filters; Humidity; Indoor environments; Microorganisms; Testing; Volatile organic compounds; Yarn;
fLanguage
English
Publisher
ieee
Conference_Titel
Bioinformatics and Biomedical Engineering , 2009. ICBBE 2009. 3rd International Conference on
Conference_Location
Beijing
Print_ISBN
978-1-4244-2901-1
Electronic_ISBN
978-1-4244-2902-8
Type
conf
DOI
10.1109/ICBBE.2009.5162827
Filename
5162827
Link To Document