• DocumentCode
    2510573
  • Title

    An evaluation of PV rural electrification system in Kenteng, Gunung Kidul, Indonesia

  • Author

    Lubis, Abubakar ; Udin, Zhanggischan

  • Author_Institution
    Agency for Assessment & Application of Technol., Jakarta, Indonesia
  • fYear
    1988
  • fDate
    1988
  • Firstpage
    1216
  • Abstract
    An evaluation of a PV rural electrification system is reported. The loads are the electricity for 85 private houses, a school, 20 sets of street lighting, a mosque, a refrigerator, and a public television. The system consists of 19 kWp PV arrays with 1600 Ah batteries. The output of the PV arrays is converted into AC power using three inverters. Two inverters are three phase, 220/380 V, and the other is one phase, 220 V. The one-phase inverter is operated for 24 hours and the others are operated for 16 hours during the night. The operation time of the two inverters can be adjusted by a timer in the control panel. The system is also provided with data gathering devices for evaluation purposes.
  • Keywords
    invertors; photovoltaic power systems; secondary cells; solar cell arrays; 19 kW; 220 V; 380 V; AC power; Indonesia; PV arrays; PV power systems; batteries; evaluation; inverters; loads; rural electrification system; secondary cells; Batteries; Educational institutions; Fires; Inverters; Lamps; Phased arrays; Photovoltaic systems; Power generation; Refrigeration; Solar power generation; TV;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Photovoltaic Specialists Conference, 1988., Conference Record of the Twentieth IEEE
  • Conference_Location
    Las Vegas, NV, USA
  • Type

    conf

  • DOI
    10.1109/PVSC.1988.105897
  • Filename
    105897