• DocumentCode
    2512454
  • Title

    A novel IMC cascade control structure of super-heated steam temperature system for super-critical coal-fired boilers

  • Author

    Wei, Le ; Fang, Fang

  • Author_Institution
    Dept. of Autom., North China Electr. Power Univ., Baoding, China
  • fYear
    2011
  • fDate
    23-25 May 2011
  • Firstpage
    641
  • Lastpage
    645
  • Abstract
    Super-heated steam temperature control system is very important for the safe and economic operation of super-critical coal-fired boilers. Basing on internal model control (IMC) method, a novel super-heated steam temperature control structure is presented. In this structure, two internal model controllers are cascaded to guarantee the accuracy and disturbance rejection performance of whole system. The parameters tuning steps of the two controllers are also given. To verify the effectiveness, three simulation tests are taken. The simulation results show that the proposed structure has good tracking, anti-disturbance and load adaptability performances.
  • Keywords
    boilers; cascade control; coal; heating; temperature control; IMC cascade control structure; disturbance rejection performance; internal model control method; load adaptability; parameter tuning steps; simulation tests; super-critical coal fired boiler; super-heated steam temperature control system; Adaptation models; Load modeling; Temperature; Temperature control; Transfer functions; Tuning; Cascade control structure; Internal model control; Super-critical coal-fired boiler; Super-heated steam temperature;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Control and Decision Conference (CCDC), 2011 Chinese
  • Conference_Location
    Mianyang
  • Print_ISBN
    978-1-4244-8737-0
  • Type

    conf

  • DOI
    10.1109/CCDC.2011.5968261
  • Filename
    5968261