DocumentCode
2512480
Title
Thermal dissipation characteristics of a non-hermetic metal dual in-line package
Author
Pasqualoni, A. ; Crane, J. ; DiOrio, M.
Author_Institution
Olin Res. Labs., New Haven, CT, USA
fYear
1988
fDate
10-12 Feb 1988
Firstpage
67
Lastpage
77
Abstract
A study is described that evaluated the benefits of a metal cavity package on junction temperature and examined consequences of die-attach methods on a device´s thermal properties. The measurements made to establish some of the factors affecting thermal transfer are outlined. Both infrared (IR) thermography and standard measurement methods were used to determine the thermal resistance for both a standard plastic dual-in-line package (P-DIP) and metal cavity package. The benefits of both approaches in assessing general thermal characteristics of the packages are discussed. The use of a metal cavity package was found to provide an excellent means of heat removal from the base of the die as long as die attach methods are sound, and the die attach medium is thermally conductive. It is also shown that it is possible to examine heat paths from the die to the case both qualitatively and quantitatively by IR thermography
Keywords
heat transfer; infrared imaging; packaging; thermal resistance measurement; IR thermography; die-attach methods; heat removal; junction temperature; metal cavity package; nonhermetic metal dual in line package; standard plastic dual-in-line package; thermal dissipation characteristics; thermal resistance; thermal transfer; Copper alloys; Heat sinks; Infrared detectors; Lead; Microassembly; Semiconductor device measurement; Semiconductor device packaging; Temperature; Testing; Thermal conductivity;
fLanguage
English
Publisher
ieee
Conference_Titel
Semiconductor Thermal and Temperature Measurement Symposium, 1988. SEMI-THERM IV., Fourth Annual IEEE
Conference_Location
San Diego, CA
Type
conf
DOI
10.1109/SEMTHE.1988.10600
Filename
10600
Link To Document