• DocumentCode
    2512896
  • Title

    A few aspects concerning the squirrel cage induction motors efficiency improvement

  • Author

    Torac, Ileana

  • Author_Institution
    Romanian Acad. - Timisoara Branch, Timisoara, Romania
  • fYear
    2012
  • fDate
    24-26 May 2012
  • Firstpage
    440
  • Lastpage
    744
  • Abstract
    The paper investigates the possibility to improve the efficiency of the squirrel cage induction motors. One analyzes the variation of the machines efficiency depending on the relative torque. The considered low voltage three-phase motors are the existing ones, having the rated power between 0.55 kW and 37 kW and the number of poles 4 and 6 respectively. The paper deals with “no tool cost” or “low tool cost” solutions. It is proposed a solution for the induction machine efficiency improvement, at full and partial-load regime.
  • Keywords
    squirrel cage motors; induction machine efficiency improvement; low voltage three-phase motors; power 0.55 kW to 37 kW; relative torque; squirrel cage induction motor efficiency; Copper; Induction motors; Low voltage; Magnetic flux density; Rotors; Stators; Torque;
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Optimization of Electrical and Electronic Equipment (OPTIM), 2012 13th International Conference on
  • Conference_Location
    Brasov
  • ISSN
    1842-0133
  • Print_ISBN
    978-1-4673-1650-7
  • Electronic_ISBN
    1842-0133
  • Type

    conf

  • DOI
    10.1109/OPTIM.2012.6231913
  • Filename